Water Quality Association
02/03/2012


US EPA STANDARD FOR MICROBIOLOGICAL WATER PURIFIERS

GUIDE STANDARD AND PROTOCOL

ABOUT THE STANDARD The guide standard and testing protocol was developed to be useful in a number of ways: As a basic framework, starting point for the testing and evaluation of microbiological water purifiers for EPA registration. As a guide to the acceptance of water treatment units for compliance with Safe Drinking water Act requirements where point of use units may be needed temporarily to treat a contaminated public water supply or for emergency situations, but not for use in extreme overseas situations of for the conversion of waste water to microbiological potable water. As a testing guide to manufacturers wishing to have their units considered as microbiological water purifiers, whether registered or not, and for the evaluation of such testing data. As a guide to consumers regarding what they can expect from microbiological water purifiers tested according to this standard and protocol. To assist in the research and development of microbiological treatment units for possible military applications.

Replacement Components for a system may or may not reduce all reduction claims that system makes. Verify through literature what contaminant(s) each replacement component reduces. Note that replacement component(s) may be required for system to operate properly even though that same replacement component may not reduce contaminants for claims made under this standard.


EcoWater Systems, LLC
1890 Woodlane Drive
Woodbury, MN 55125
Phone: (651) 739-5330
http://www.ecowater.com

Product Type: Point-of-Use
Model Flow Rate Capacity Reduction Claims
EPS 1000 0.74 gpm 350 gallons Bacteria
Cyst
Virus

GE Water & Process Technologies
5316 John Lucas Drive
Burlington
Ontario, L7L 6A6
Phone: (905) 332-6694
http://www.ge.com/water

Product Type: Point-of-Entry
Model Flow Rate Capacity Reduction Claims
UF 211 11.0 gpm 130,000 gallons Bacteria
Cyst
Virus
UFC 211 4.5 gpm 130,000 gallons Bacteria
Cyst
Virus

HomeFlow BV
Naritaweg 165,
1007 JE
Amsterdam,,
Phone: +972 54 433 8483

Product Type: Plumbed-In with Reservoir
Model Flow Rate Capacity Reduction Claims
PURE 2 GO 0.9 gpm 2640 gallons Bacteria
Cyst
Virus

Hydro-Photon
262 Ellsaworth Rd.
Blue Hill, ME 04614
Phone: (207) 374-5800
http://www.steripen.com

Product Type: Point-of-Use
Model Flow Rate Capacity Reduction Claims
SteriPEN 1 2 N/A N/A Bacteria
Cyst
Virus
Sidewinder     Bacteria
Cyst
Virus
1: This sytem has been certified to be used with a maximum of 1 liter of water per use and a disinfection time of a maximum of 90 seconds per use.
2: This certification includes the following models: Classic, Journey, Adventurer, Traveler, AdventurerOPTI, Emergency, Freedom, Defender, Protector and Traveler Mini.

Innovative Water Technologies, Inc.
IWT Headquarters
29625 Industrial Park Rd
Rocky Ford, CO 81067
Phone: 719-254-4426
http://www.innovativeh2o.com


Product Type: Point-of-Use
Model Flow Rate Capacity Reduction Claims
Sunspring ss24 1 4.5 gpm 6,480 gpd Bacteria
Cyst
Virus
Sunspring ss24DPR 1 4.5 gpm 6,480 gpd Bacteria
Cyst
Virus
Sunspring ss24MS 4.5 gpm 6,480 gpd Bacteria
Cyst
Virus
Sunspring ss24RWH 1 4.5 gpm 6,480 gpd Bacteria
Cyst
Virus
Sunspring ss36 1 9 gpm 12,960 gpd Bacteria
Cyst
Virus
1: The GAC pre-filter included with some models has a lifetime capacity of 130,000 gallons before needing replacement.

Norit Filtrix
Twentepoort Oost 24
7609 RG
Almelo,
Phone: +31 33 4220440
http://www.filtrix.com


Product Type: Point-of-Use
Model Flow Rate Capacity Reduction Claims
H2OK WaterPurifier 1 GPM 1000 Gallons Bacteria
Cyst
Virus
H2OK WaterPurifier+ 1 GPM 1000 Gallons Bacteria
Cyst
Virus

Protect Plus, LLC
11515 Vanstory Dr.
Suite 135
Huntersville, NC 28078
Phone: (704)875-0366
Protect Plus, LLC
http://www.dupont.com


Product Type: Point-of-Use
Model Flow Rate Capacity Reduction Claims
WFQT390005 1 1.0 1000 Bacteria
Cyst
Virus
1: This system also meets the requirements of the NSF P-231 protocol.

Waterlogic International, Ltd.
Level 5, Belvedere, Basing View
Basingstoke, RG21 4HG
Phone: 402-884-7212
http://www.waterlogic.com/


Product Type: Point-of-Use
Model Flow Rate Capacity Reduction Claims
FW2 HC .42 2000 Bacteria
Cyst
Virus


Disclaimer:
Listing in these directories does not constitute an endorsement, guarantee, or warranty of any kind by Water Quality Association or its members of any of the products contained in them.
Every effort has been made to verify the accuracy of all listings in this directory. The association can assume no liability for errors or omissions.



Water Quality Association: Back
Fri, Feb 3, 2012


Copyright 2012 by the Water Quality Association – All rights reserved.
Water Quality Association
International Headquarters & Laboratory
4151 Naperville Road
Lisle, IL 60532-3696
USA
630 505 0160, Fax 630 505 9637
info@wqa.org, www.wqa.org