Water Quality Association

8/16/2017

WQA Logo

CERTIFIED DRINKING WATER SYSTEM COMPONENTS

NSF/ANSI 61 - 2016: Drinking Water System Components - Health Effects

Show Description
C.I.M. Industries Inc.
23 Elm Street Peterborough,  NH  03458 united states
    • Product Type: Coating
      • Brand Name
        Model
        Water Contact Temp
        Water Contact Material
        Size
      • CIM 1000TG 1 2 3 4 5 6 7 8 9 10 11
        Cold (23C)
        Polyurethane
        N/A
  • 1 Maximum surface area to volume ratio of 21.3 sq cm/L for tanks greater than 5,000 gallons for cold applications as barrier materials.
  • 2 CIM 1000 Trowel Grade consists of CIM 1000TG premix and CIM 1000TG activator mixed in a 36 to 5.5 ratio by weight.
  • 3 Also Classified is CIM VOC Bonding Agent as an optional primer (minimum coverage rate of 300 ft 2/gal with a minimum drying time of 30 minutes). The following use restrictions apply: Number of coats: as many as needed to reach the Maximum Field Use Dry Film Thickness of 60 mils, Minimum Cure Temperature: 60 F, Re-coat/cure time: 3 hours/ 2 weeks as barrier materials.
  • 4 Maximum surface area to volume ratio of 13.5 sq cm/L for tanks greater than 20,000 gallons for cold applications as barrier materials.
  • 5 Also Classified is CIM VOC Bonding Agent as an optional primer (minimum coverage rate of 300 ft 2/gal with a minimum drying time of 30 minutes). The following use restrictions apply: Number of coats: as many as needed to reach the Maximum Field Use Dry Film Thickness of 80 mils, Minimum Cure Temperature: 60 F, Re-coat/cure time: 3 hours/1 week for cold applications as barrier materials.
  • 6 Washing procedure: These coatings must be washed according to CIM's "Decontamination or washing procedures for potable water tank and fish pond services" before being put into service.
  • 7 The coating is approved to be used over Scrim, which is a polyethylene material which is typically applied over the crack before the coating is applied for barrier materials.
  • 8 Maximum surface area to volume ratio of 21.3 sq cm/L for use up to 10% of 10 gal. tanks or greater for joining and sealing materials.
  • 9 Also Classified as CIM VOC Bonding Agent as an optional primer (minimum coverage rate of 300 ft 2/gal witha minimum drying time of 30 minutes). The following use instructions apply: Minimum cure temperature: 60 F - Minimum cure time: 2 weeks for cold application as joining and sealing materials.
  • 10 When this product is sold in a caulk type cartridge, the total coverage is limited to 5% of the total approved surface area.
  • 11 Also Classified is CIM VOC Bonding Agent as an optional primer (minimum coverage rate of 300 ft 2/gal with a minimum drying time of 30 minutes). The following use restrictions apply: Number of coats: as many as needed to reach the Maximum Field Use Dry Film Thickness of 80 mils, Minimum Cure Temperature: 60 F, Re-coat/cure time: 3 hours/1 day.